First generation›Documents

Maintenance manual, Section 6 · Site-authored bench test

Bench test: REC output & REP EQ board (PA-286A)

For fixing a 2S with a multimeter. Pick your model, set the deck to stop or play or to record, and set the speed switch; each test point then shows the DC voltage it should read, as a band. Type in what your meter shows and each reading is flagged in band, low or high. Once a reading is out of band, the page ranks the single faults that would explain your readings, and suggests the reading that would best tell them apart.

These values are simulated and have not yet been checked on a real deck. They come from this site's simulation of the redrawn PA-286A sheet, run 200 times with the parts spread across their tolerances. Where the PA-286A sheet and Otari's AF230A sheet disagree (C28/C128, C29/C129, R31/R131, R57/R157, RB38/RB138; the board prints RB38 as “R38”), pick the revision your board matches; if you are not sure, the band covers both.

The test points are every transistor lead, every resistor, capacitor and pot lead that is not on ground, and the supply rails. Each part has a link to its place on Otari's board layout. The layout prints the right channel's parts with the left channel's numbers: the “R31” beside TR105, in the half marked (R), is R131.

Model(2SD, 2SHD: not yet known which column)
Deck is in
Speed switch
Sheet revision

Black probe on the board's GND terminal; DC volts. Readings are kept in this browser only. ·

Likely causes

Type readings into the tables below. Start with +B, then the transistor leads of the stage that misbehaves.

Supply

Test pointExpected (V)TypicalYour readingNote
+B terminal27.41 – 30.6129.00
+24V terminal22.70 – 25.3224.00
Reproduce supply rail, left18.54 – 21.4220.08
Reproduce supply rail, right18.50 – 21.5020.08
Record supply rail, left26.57 – 29.7928.24 or 28.09
Record supply rail, right26.55 – 29.7928.24 or 28.09
Oscillator supply (T2 centre tap)0.00 – 0.210.08

Reproduce EQ, left

Test pointExpected (V)TypicalYour readingNote
R96, end at C51-0.02 – 0.020.00
R51, end at Reproduce supply rail, left18.54 – 21.4220.08
R51, end at R529.09 – 10.7810.02
R52, end at R519.09 – 10.7810.02
C51 + lead9.07 – 10.739.96
C51 − lead-0.02 – 0.020.00
R53, end at Tr6 base9.07 – 10.739.96
R53, end at R519.09 – 10.7810.02
C52, end at Tr6 base9.07 – 10.739.96
C52, end at Tr6 emitter8.48 – 10.139.37
C73 + lead9.09 – 10.7810.02
Tr6 emitter8.48 – 10.139.37
Tr6 base9.07 – 10.739.96
Tr6 collector14.73 – 17.3216.09
R54, end at Reproduce supply rail, left18.54 – 21.4220.08
R54, end at Tr6 collector14.73 – 17.3216.09
R55, end at Tr6 emitter8.48 – 10.139.37
R55, end at R568.46 – 10.119.34
R56, end at R558.46 – 10.119.34
C53 + lead8.46 – 10.119.34
R98, end at Tr6 emitter8.48 – 10.139.37
R98, end at Tr15 source8.48 – 10.139.37
R61, end at Tr15 source8.48 – 10.139.37
R61, end at Tr15 drain8.48 – 10.139.37
Tr15 source8.48 – 10.139.37
Tr15 gate0.01 – 10.440.03 the meter loads this point, so its reading is not used to rank faults: a 10 MΩ meter reads about 0.03 V here, a higher-impedance meter up to 9.67 V
Tr15 drain8.48 – 10.139.37
C54, end at Tr6 emitter8.48 – 10.139.37
C54, end at Tr7 collector9.22 – 11.5410.29
C55, end at Tr15 drain8.48 – 10.139.37
C55, end at R578.58 – 10.859.62
R57, end at Tr15 drain8.48 – 10.139.37
R57, end at C558.58 – 10.859.62
R60, end at C558.58 – 10.859.62
R60 wiper8.56 – 10.879.62
R60, end at Tr8 emitter8.56 – 10.879.62
Tr7 emitter15.33 – 17.9216.69
Tr7 base14.73 – 17.3216.09
Tr7 collector9.22 – 11.5410.29
R58, end at Reproduce supply rail, left18.54 – 21.4220.08
R58, end at Tr7 emitter15.33 – 17.9216.69
R59, end at Tr7 collector9.22 – 11.5410.29
C56 + lead15.33 – 17.9216.69
Tr8 emitter8.56 – 10.879.62
Tr8 base9.22 – 11.5410.29
Tr8 collector18.34 – 21.2419.89
R97, end at Reproduce supply rail, left18.54 – 21.4220.08
R97, end at Tr8 collector18.34 – 21.2419.89
R62, end at Tr8 emitter8.56 – 10.879.62
C57 + lead8.56 – 10.879.62
C57 − lead-0.02 – 0.020.00
R63, end at C57-0.02 – 0.020.00
R63 wiper-0.02 – 0.020.00
R65, end at R63-0.02 – 0.020.00
R65 wiper-0.02 – 0.020.00
C58 + lead18.54 – 21.4220.08
R64, end at Reproduce supply rail, left18.54 – 21.4220.08
R64, end at Tr305 drain27.41 – 30.6129.00

Reproduce EQ, right

Test pointExpected (V)TypicalYour readingNote
R196, end at C151-0.02 – 0.020.00
R152, end at R1519.12 – 10.7610.02
R151, end at R1529.12 – 10.7610.02
R151, end at Reproduce supply rail, right18.50 – 21.5020.08
C151 + lead9.09 – 10.729.96
C151 − lead-0.02 – 0.020.00
R153, end at R1529.12 – 10.7610.02
R153, end at Tr106 base9.09 – 10.729.96
C152, end at Tr106 base9.09 – 10.729.96
C152, end at Tr106 emitter8.50 – 10.129.37
C173 + lead9.12 – 10.7610.02
Tr106 emitter8.50 – 10.129.37
Tr106 base9.09 – 10.729.96
Tr106 collector14.57 – 17.4016.09
R154, end at Tr106 collector14.57 – 17.4016.09
R154, end at Reproduce supply rail, right18.50 – 21.5020.08
R155, end at R1568.48 – 10.099.34
R155, end at Tr106 emitter8.50 – 10.129.37
R156, end at R1558.48 – 10.099.34
C153 + lead8.48 – 10.099.34
R198, end at Tr106 emitter8.50 – 10.129.37
R198, end at Tr115 source8.51 – 10.129.37
R161, end at Tr115 source8.51 – 10.129.37
R161, end at Tr115 drain8.51 – 10.129.37
Tr115 source8.51 – 10.129.37
Tr115 gate0.01 – 10.430.03 the meter loads this point, so its reading is not used to rank faults: a 10 MΩ meter reads about 0.03 V here, a higher-impedance meter up to 9.67 V
Tr115 drain8.51 – 10.129.37
C154, end at Tr106 emitter8.50 – 10.129.37
C154, end at Tr107 collector9.20 – 11.7710.29
C155, end at Tr115 drain8.51 – 10.129.37
C155, end at R1578.54 – 11.059.62
R157, end at Tr115 drain8.51 – 10.129.37
R157, end at C1558.54 – 11.059.62
R160, end at C1558.54 – 11.059.62
R160 wiper8.54 – 11.099.62
R160, end at Tr108 emitter8.54 – 11.099.62
Tr107 emitter15.17 – 18.0016.69
Tr107 base14.57 – 17.4016.09
Tr107 collector9.20 – 11.7710.29
R158, end at Tr107 emitter15.17 – 18.0016.69
R158, end at Reproduce supply rail, right18.50 – 21.5020.08
R159, end at Tr107 collector9.20 – 11.7710.29
C156 + lead15.17 – 18.0016.69
Tr108 emitter8.54 – 11.099.62
Tr108 base9.20 – 11.7710.29
Tr108 collector18.30 – 21.3119.89
R197, end at Tr108 collector18.30 – 21.3119.89
R197, end at Reproduce supply rail, right18.50 – 21.5020.08
R162, end at Tr108 emitter8.54 – 11.099.62
C157 + lead8.54 – 11.099.62
C157 − lead-0.02 – 0.020.00
R163 wiper-0.02 – 0.020.00
R163, end at C157-0.02 – 0.020.00
R165 wiper-0.02 – 0.020.00
R165, end at R163-0.02 – 0.020.00
C158 + lead18.50 – 21.5020.08
R164, end at Reproduce supply rail, right18.50 – 21.5020.08
R164, end at Tr305 drain27.41 – 30.6129.00

Reproduce EQ speed switching

Test pointExpected (V)TypicalYour readingNote
R301, end at C30127.41 – 30.6129.00
R301, end at R30227.41 – 30.6129.00
R302, end at R30127.41 – 30.6129.00
C301 + lead27.41 – 30.6129.00

Record amplifier, left

Test pointExpected (V)TypicalYour readingNote
R27, end at C18-0.02 – 0.020.00
R27, end at R30-0.02 – 0.020.00
C18, end at R27-0.02 – 0.020.00
C18, end at C19-0.02 – 0.020.00
C19, lead 1-0.02 – 0.020.00
C19, end at C18-0.02 – 0.020.00
R28, end at C18-0.02 – 0.020.00
R28 wiper-0.02 – 0.020.00
R28, lead 3-0.02 – 0.020.00
C20, end at R27-0.02 – 0.020.00
C20, end at C21-0.02 – 0.020.00
C21, lead 1-0.02 – 0.020.00
C21, end at C20-0.02 – 0.020.00
R29, end at C20-0.02 – 0.020.00
R29 wiper-0.02 – 0.020.00
R29, end at C22-0.02 – 0.020.00
C22, end at R29-0.02 – 0.020.00
C22, lead 2-0.02 – 0.020.00
R30, end at R27-0.02 – 0.020.00
C23 + lead4.03 – 5.754.47 or 5.22
C23 − lead-0.02 – 0.020.00
R31, end at Record supply rail, left26.57 – 29.7928.24 or 28.09
R31, end at Tr5 base4.03 – 5.754.47 or 5.22
R32, end at Tr5 base4.03 – 5.754.47 or 5.22
Tr5 emitter3.35 – 5.053.79 or 4.53
Tr5 base4.03 – 5.754.47 or 5.22
Tr5 collector4.59 – 12.0310.10 or 6.39
R33, end at Record supply rail, left26.57 – 29.7928.24 or 28.09
R33, end at Tr5 collector4.59 – 12.0310.10 or 6.39
C25 + lead4.59 – 12.0310.10 or 6.39
C25 − lead-0.02 – 0.020.00
C26, end at C25-0.02 – 0.020.00
C26, end at L1-0.02 – 0.020.00
L1, end at C25-0.02 – 0.020.00
L1, end at C26-0.02 – 0.020.00
L2, end at Tr5 emitter3.35 – 5.053.79 or 4.53
L2, end at RB383.35 – 5.053.79 or 4.53
RB38, end at Tr5 emitter3.35 – 5.053.79 or 4.53
RB38, end at L23.35 – 5.053.79 or 4.53
R34, end at Tr5 emitter3.35 – 5.053.79 or 4.53
R34, end at R350.72 – 1.200.86 or 1.02
R35, end at R340.72 – 1.200.86 or 1.02
C24 + lead0.72 – 1.200.86 or 1.02
R36, end at L23.35 – 5.053.79 or 4.53
R36, end at C273.35 – 5.053.79 or 4.53
C27, end at R363.35 – 5.053.79 or 4.53
C28, end at R363.35 – 5.053.79 or 4.53
C28, lead 2-0.02 – 0.020.00
C29, end at C300.01 – 2.540.04 the meter loads this point, so its reading is not used to rank faults: a 10 MΩ meter reads about 0.04 V here, a higher-impedance meter up to 1.89 V
C30, end at C290.01 – 2.540.04 the meter loads this point, so its reading is not used to rank faults: a 10 MΩ meter reads about 0.04 V here, a higher-impedance meter up to 1.89 V
C30, lead 2-0.02 – 0.020.00
C31 + lead26.57 – 29.7928.24 or 28.09
R37, end at Record supply rail, left26.57 – 29.7928.24 or 28.09
R37, end at Tr305 drain27.41 – 30.6129.00

Record amplifier, right

Test pointExpected (V)TypicalYour readingNote
R127, end at C118-0.02 – 0.020.00
R127, end at R130-0.02 – 0.020.00
C118, end at R127-0.02 – 0.020.00
C118, end at C119-0.02 – 0.020.00
C119, lead 1-0.02 – 0.020.00
C119, end at C118-0.02 – 0.020.00
R128, end at C118-0.02 – 0.020.00
R128 wiper-0.02 – 0.020.00
R128, lead 3-0.02 – 0.020.00
C120, end at R127-0.02 – 0.020.00
C120, end at C121-0.02 – 0.020.00
C121, lead 1-0.02 – 0.020.00
C121, end at C120-0.02 – 0.020.00
R129, end at C120-0.02 – 0.020.00
R129 wiper-0.02 – 0.020.00
R129, end at C122-0.02 – 0.020.00
C122, end at R129-0.02 – 0.020.00
C122, lead 2-0.02 – 0.020.00
R130, end at R127-0.02 – 0.020.00
C123 + lead4.03 – 5.704.47 or 5.22
C123 − lead-0.02 – 0.020.00
R132, end at Tr105 base4.03 – 5.704.47 or 5.22
R131, end at Tr105 base4.03 – 5.704.47 or 5.22
R131, end at Record supply rail, right26.55 – 29.7928.24 or 28.09
Tr105 emitter3.34 – 5.003.79 or 4.53
Tr105 base4.03 – 5.704.47 or 5.22
Tr105 collector4.67 – 12.0210.10 or 6.39
R133, end at Tr105 collector4.67 – 12.0210.10 or 6.39
R133, end at Record supply rail, right26.55 – 29.7928.24 or 28.09
C125 + lead4.67 – 12.0210.10 or 6.39
C125 − lead-0.02 – 0.020.00
C126, end at C125-0.02 – 0.020.00
C126, end at L101-0.02 – 0.020.00
L101, end at C125-0.02 – 0.020.00
L101, end at C126-0.02 – 0.020.00
L102, end at Tr105 emitter3.34 – 5.003.79 or 4.53
L102, end at RB1383.34 – 5.003.79 or 4.53
RB138, end at Tr105 emitter3.34 – 5.003.79 or 4.53
RB138, end at L1023.34 – 5.003.79 or 4.53
R134, end at R1350.73 – 1.180.86 or 1.02
R134, end at Tr105 emitter3.34 – 5.003.79 or 4.53
R135, end at R1340.73 – 1.180.86 or 1.02
C124 + lead0.73 – 1.180.86 or 1.02
R136, end at L1023.34 – 5.003.79 or 4.53
R136, end at C1273.34 – 5.003.79 or 4.53
C127, end at R1363.34 – 5.003.79 or 4.53
C128, lead 1-0.02 – 0.020.00
C128, end at R1363.34 – 5.003.79 or 4.53
C129, end at C1300.01 – 2.510.04 the meter loads this point, so its reading is not used to rank faults: a 10 MΩ meter reads about 0.04 V here, a higher-impedance meter up to 1.89 V
C130, lead 1-0.02 – 0.020.00
C130, end at C1290.01 – 2.510.04 the meter loads this point, so its reading is not used to rank faults: a 10 MΩ meter reads about 0.04 V here, a higher-impedance meter up to 1.89 V
C131 + lead26.55 – 29.7928.24 or 28.09
R137, end at Record supply rail, right26.55 – 29.7928.24 or 28.09
R137, end at Tr305 drain27.41 – 30.6129.00

Bias oscillator and record switching

Test pointExpected (V)TypicalYour readingNote
R311, end at Tr305 drain27.41 – 30.6129.00
R311, end at Tr303 collector0.73 – 0.800.77
R312, end at Tr305 drain27.41 – 30.6129.00
R312, end at Tr305 gate-0.01 – 0.030.01
Tr305 source0.49 – 0.820.65
Tr305 gate-0.01 – 0.030.01
Tr305 drain27.41 – 30.6129.00
R313, end at Tr305 gate-0.01 – 0.030.01
R313, end at Tr305 source0.49 – 0.820.65
R314, end at Tr305 source0.49 – 0.820.65
R314, end at Tr306 base0.49 – 0.810.65
Tr303 base-0.02 – 0.020.00
Tr303 collector0.73 – 0.800.77
Tr304 base0.73 – 0.800.77
Tr304 collector-0.01 – 0.030.01
R309, end at Tr303 base-0.02 – 0.020.00
R309, lead 2-0.02 – 0.020.00
R310, end at Tr303 base-0.02 – 0.020.00
Tr306 emitter0.00 – 0.210.08
Tr306 base0.49 – 0.810.65
Tr306 collector27.36 – 30.5628.95
R315, end at Tr305 drain27.41 – 30.6129.00
R315, end at Tr306 collector27.36 – 30.5628.95
C304 + lead0.49 – 0.810.65
C305 + lead0.00 – 0.210.08
R316, end at Tr305 drain27.41 – 30.6129.00
R316, end at R3170.59 – 0.700.64
R317, end at R3160.59 – 0.700.64
C306, end at R3160.59 – 0.700.64
Tr307 emitter-0.01 – 0.070.03
Tr307 base0.59 – 0.700.64
Tr307 collector0.00 – 0.100.04
R318, end at Tr307 collector0.00 – 0.100.04
R318, lead 20.00 – 0.210.08
R320, end at Tr307 emitter-0.01 – 0.070.03
Tr308 emitter-0.01 – 0.080.03
Tr308 base0.59 – 0.700.64
Tr308 collector0.00 – 0.100.04
R321, end at Tr308 emitter-0.01 – 0.080.03
R319, end at Tr308 collector0.00 – 0.100.04
R319, lead 20.00 – 0.210.08
C307, lead 1-0.02 – 0.020.00
C32, end at C132-0.02 – 0.020.00
C32, end at R38-0.02 – 0.020.00
R38, end at C32-0.02 – 0.020.00
R38 wiper-0.02 – 0.020.00
R38, lead 3-0.02 – 0.020.00
C132, end at C32-0.02 – 0.020.00
C132, end at R138-0.02 – 0.020.00
R138, end at C132-0.02 – 0.020.00
R138 wiper-0.02 – 0.020.00
R138, lead 3-0.02 – 0.020.00
R322, lead 1-0.02 – 0.020.00
R322, end at L301-0.02 – 0.020.00
L301, end at R322-0.02 – 0.020.00
C302 + lead22.70 – 25.3224.00
C302 − lead22.70 – 25.3224.00
R303, end at C30222.70 – 25.3224.00
R303, end at Tr301 collector22.70 – 25.3224.00
C303 + lead22.70 – 25.3224.00
C303 − lead22.70 – 25.3224.00
R304, end at C30322.70 – 25.3224.00
R304, end at Tr302 collector22.70 – 25.3224.00
Tr301 base-0.02 – 0.020.00
Tr301 collector22.70 – 25.3224.00
R305, lead 1-0.02 – 0.020.00
R305, end at Tr301 base-0.02 – 0.020.00
R306, end at Tr301 base-0.02 – 0.020.00
Tr302 base-0.02 – 0.020.00
Tr302 collector22.70 – 25.3224.00
R307, lead 1-0.02 – 0.020.00
R307, end at Tr302 base-0.02 – 0.020.00
R308, end at Tr302 base-0.02 – 0.020.00

How the bands were made

  • Each band is the spread of 200 simulated boards: resistors ±5 % uniform, +B ±5 % uniform, transistor gain uniform across each type's hFE range, JFET IDSS across the grade band, pinch-off ±20 %, relay operate and release voltages ±20 %. The band runs from the 1st to 99th percentile, widened by ±(0.5 % + 20 mV) for the meter. The typical value is the board with every part at its printed value.
  • The meter is taken as 10 MΩ to ground; where it moves a point by more than 2 % or 50 mV the band is what it reads.
  • The faults are 255 single faults: transistor leads open or shorted, resistors open or drifted to about twice their value (47k and up, as old carbon resistors drift high), electrolytics shorted or leaky, diodes open or shorted, relay coils open or contacts stuck, pot wipers open. Each was simulated alone (each fault alone, nominal parts; a point within a quarter of the band's width of an edge is counted either way).
  • No pot on this board sets a DC voltage, so alignment does not move these readings.

What the simulation assumes

  • Transistor gain (hFE) ranges for the 2SC1211, 2SC373, 2SC644 and 2SA666: minimum from catalogue listings, maximum assumed. The 2SC828A and 2SC1384 ranges come from their data sheets.
  • The 2SK34 JFETs' IDSS grade bands (grades C and D): assumed, as no grade table was found.
  • The relays' coil resistance and operate and release voltages: assumed, as the sheet does not name the relays.
  • D301 (SM-1-02) forward voltage: assumed.
  • The bias transformer T2's windings: assumed; its tuning and the erase head are fitted to Otari's printed 133 kHz and 80 mA.
Faults no DC reading can find (65)

These leave every test point in band in every condition. They need a signal test (a scope or a tone through the deck), not a meter.

  • C124 leaky (100µ/6.3V; about 10 kΩ across it)
  • C131 leaky (47µ/35V; about 10 kΩ across it)
  • C24 leaky (100µ/6.3V; about 10 kΩ across it)
  • C305 leaky (47µ/35V; about 10 kΩ across it)
  • C31 leaky (47µ/35V; about 10 kΩ across it)
  • D301 open
  • D301 shorted
  • D302 open
  • D302 shorted
  • D303 open
  • D303 shorted
  • R127 open (10k)
  • R128 wiper open
  • R129 wiper open
  • R130 open (20k)
  • R138 wiper open
  • R153 drifted high (150k, now about twice)
  • R157 open (180k or 200k)
  • R157 drifted high (180k or 200k, now about twice)
  • R160 wiper open
  • R161 open (2k)
  • R163 wiper open
  • R165 wiper open
  • R196 open (100k)
  • R196 drifted high (100k, now about twice)
  • R198 open (2k)
  • R27 open (10k)
  • R28 wiper open
  • R29 wiper open
  • R30 open (20k)
  • R301 drifted high (100k, now about twice)
  • R302 open (100k)
  • R302 drifted high (100k, now about twice)
  • R303 open (510)
  • R304 open (510)
  • R306 open (10k)
  • R308 open (10k)
  • R309 drifted high (100k, now about twice)
  • R310 open (100k)
  • R310 drifted high (100k, now about twice)
  • R312 open (470k)
  • R312 drifted high (470k, now about twice)
  • R322 open (24)
  • R38 wiper open
  • R53 drifted high (150k, now about twice)
  • R57 open (180k or 200k)
  • R57 drifted high (180k or 200k, now about twice)
  • R60 wiper open
  • R61 open (2k)
  • R63 wiper open
  • R65 wiper open
  • R96 open (100k)
  • R96 drifted high (100k, now about twice)
  • R98 open (2k)
  • RB138 open (5.1k)
  • RB38 open (5.1k)
  • RL1 coil open
  • RL2 stuck operated
  • RL3 stuck operated
  • Tr115 drain open
  • Tr115 source open
  • Tr115 drain-source short
  • Tr15 drain open
  • Tr15 source open
  • Tr15 drain-source short

See also the parts list (every value, with the DC voltage at every lead) and Otari's sheet and layout in Section 6. Simulated in KiCad 10.0.4 and ngspice.