For fixing a 2S with a multimeter. Set whether the deck is stopped or playing or recording, and where the RECORD and SEL REP switches stand; each test point then shows the DC voltage it should read, as a band. Type in what your meter shows and each reading is flagged in band, low or high. Once a reading is out of band, the page ranks the single faults that would explain your readings, and suggests the reading that would best tell them apart.

These values are simulated and have not yet been checked on a real deck. They come from this site's simulation of the redrawn PA-287A sheet, run 200 times with the parts spread across their tolerances. The mic, line and SEL REP amplifiers read the same whatever the deck and the switches do: only R325 and R326, which carry the record command on to PA-286A, change. Set the switches as they stand for the channel you are measuring.

The test points are every transistor lead, every resistor, capacitor and pot lead that is not on ground, and the supply rails. Each part has a link to its place on Otari's PM918A board layout. The mic and line amplifiers are mirrored about the middle of the board, the right channel above and the left below. The board prints the right channel's transistors as TR101 to TR104 but most of its resistors and capacitors with the left channel's numbers: the “R1” just below TR101 is R101 (R130, the RECORD LEVEL CAL. pot, prints its own number). The SEL REP amplifiers print their own numbers, 351 on for the left channel and 371 on for the right.

Deck is in
RECORD switches
SEL REP switches

Black probe on the board's GND terminal; DC volts. Readings are kept in this browser only. ·

Likely causes

Type readings into the tables below. Start with +B, then the transistor leads of the stage that misbehaves.

Supply

Test pointExpected (V)TypicalYour readingNote
+B terminal27.42 – 30.5929.00
+24V terminal22.68 – 25.3324.00
Line amplifier rail, left (C8 +)27.05 – 30.1528.62
Line amplifier rail, right (C108 +)27.04 – 30.2028.62
Mic amplifier rail, left (C7 +)23.52 – 26.2824.92
Mic amplifier rail, right (C107 +)23.40 – 26.2924.92
SEL REP collector rail, left (C354 +)20.98 – 24.0322.51
SEL REP rail, left (C365 +)22.63 – 25.9124.32
SEL REP collector rail, right (C374 +)21.02 – 23.9522.51
SEL REP rail, right (C385 +)22.67 – 25.8624.32

Mic amplifier, left

Test pointExpected (V)TypicalYour readingNote
C1 + lead9.27 – 11.0210.18
C1 − lead-0.02 – 0.020.00
R1, end at Tr1 base9.27 – 11.0210.18
R2, end at Mic amplifier rail, left (C7 +)23.52 – 26.2824.92
R2, end at Tr1 base9.27 – 11.0210.18
C2, end at Tr1 base9.27 – 11.0210.18
C2, end at Tr1 emitter9.88 – 11.6510.80
C3 + lead10.03 – 11.7910.96
R3, end at Tr1 collector7.36 – 8.938.13
R4, end at C310.03 – 11.7910.96
R4, end at Tr1 emitter9.88 – 11.6510.80
R5, end at Mic amplifier rail, left (C7 +)23.52 – 26.2824.92
R5, end at C310.03 – 11.7910.96
R6, end at Tr1 emitter9.88 – 11.6510.80
R6, end at Tr2 collector10.80 – 13.0312.06
C4, end at Tr1 emitter9.88 – 11.6510.80
C4, end at Tr2 collector10.80 – 13.0312.06
C27, end at Tr2 collector10.80 – 13.0312.06
C27, end at Tr1 collector7.36 – 8.938.13
Tr1 emitter9.88 – 11.6510.80
Tr1 base9.27 – 11.0210.18
Tr1 collector7.36 – 8.938.13
Tr2 emitter6.71 – 8.267.47
Tr2 base7.36 – 8.938.13
Tr2 collector10.80 – 13.0312.06
C5 + lead6.71 – 8.267.47
R7, end at Tr2 emitter6.71 – 8.267.47
R8, end at Mic amplifier rail, left (C7 +)23.52 – 26.2824.92
R8, end at Tr2 collector10.80 – 13.0312.06
C6 + lead10.80 – 13.0312.06
C6 − lead-0.02 – 0.020.00
C7 + lead23.52 – 26.2824.92
R10, end at Mic amplifier rail, left (C7 +)23.52 – 26.2824.92
R10, end at Line amplifier rail, left (C8 +)27.05 – 30.1528.62

Mic amplifier, right

Test pointExpected (V)TypicalYour readingNote
C101 + lead9.14 – 11.0410.18
C101 − lead-0.02 – 0.020.00
R101, end at Tr101 base9.14 – 11.0410.18
R102, end at Tr101 base9.14 – 11.0410.18
R102, end at Mic amplifier rail, right (C107 +)23.40 – 26.2924.92
C102, end at Tr101 base9.14 – 11.0410.18
C102, end at Tr101 emitter9.76 – 11.6610.80
C103 + lead9.90 – 11.8210.96
R103, end at Tr101 collector7.39 – 9.018.13
R104, end at Tr101 emitter9.76 – 11.6610.80
R104, end at C1039.90 – 11.8210.96
R105, end at C1039.90 – 11.8210.96
R105, end at Mic amplifier rail, right (C107 +)23.40 – 26.2924.92
R106, end at Tr101 emitter9.76 – 11.6610.80
R106, end at Tr102 collector10.77 – 13.0312.06
C104, end at Tr101 emitter9.76 – 11.6610.80
C104, end at Tr102 collector10.77 – 13.0312.06
C127, end at Tr101 collector7.39 – 9.018.13
C127, end at Tr102 collector10.77 – 13.0312.06
Tr101 emitter9.76 – 11.6610.80
Tr101 base9.14 – 11.0410.18
Tr101 collector7.39 – 9.018.13
Tr102 emitter6.73 – 8.347.47
Tr102 base7.39 – 9.018.13
Tr102 collector10.77 – 13.0312.06
C105 + lead6.73 – 8.347.47
R107, end at Tr102 emitter6.73 – 8.347.47
R108, end at Tr102 collector10.77 – 13.0312.06
R108, end at Mic amplifier rail, right (C107 +)23.40 – 26.2924.92
C106 + lead10.77 – 13.0312.06
C106 − lead-0.02 – 0.020.00
C107 + lead23.40 – 26.2924.92
R110, end at Mic amplifier rail, right (C107 +)23.40 – 26.2924.92
R110, end at Line amplifier rail, right (C108 +)27.04 – 30.2028.62

Line amplifier, left

Test pointExpected (V)TypicalYour readingNote
R11, lead 1-0.02 – 0.020.00
R11, end at C9-0.02 – 0.020.00
C9 + lead10.57 – 12.7611.53 the meter loads this point, so its reading is not used to rank faults: a 10 MΩ meter reads about 11.53 V here, a higher-impedance meter up to 11.87 V
C9 − lead-0.02 – 0.020.00
R16, end at Line amplifier rail, left (C8 +)27.05 – 30.1528.62
R16, end at C1117.62 – 20.2819.02
C11 + lead17.62 – 20.2819.02
R17, end at R1617.62 – 20.2819.02
R17, end at R1810.84 – 12.6711.76
R18, end at R1710.84 – 12.6711.76
R19, end at Tr3 base10.57 – 12.7611.53 the meter loads this point, so its reading is not used to rank faults: a 10 MΩ meter reads about 11.53 V here, a higher-impedance meter up to 11.87 V
R19, end at R1710.84 – 12.6711.76
C10, end at Tr3 base10.57 – 12.7611.53 the meter loads this point, so its reading is not used to rank faults: a 10 MΩ meter reads about 11.53 V here, a higher-impedance meter up to 11.87 V
C10, end at Tr3 emitter11.45 – 13.3412.44
Tr3 emitter11.45 – 13.3412.44
Tr3 base10.57 – 12.7611.53 the meter loads this point, so its reading is not used to rank faults: a 10 MΩ meter reads about 11.53 V here, a higher-impedance meter up to 11.87 V
Tr3 collector3.40 – 4.283.78
R20, end at Line amplifier rail, left (C8 +)27.05 – 30.1528.62
R20, end at R2111.46 – 13.3512.46
R21, end at R2011.46 – 13.3512.46
R21, end at Tr3 emitter11.45 – 13.3412.44
C12 + lead11.46 – 13.3512.46
R22, end at Tr3 collector3.40 – 4.283.78
R25, end at Tr3 emitter11.45 – 13.3412.44
R25, end at C1511.45 – 13.3412.44
C15, end at R2511.45 – 13.3412.44
C15, end at Tr4 drain8.09 – 13.1811.24
C13, end at Tr3 emitter11.45 – 13.3412.44
C13, end at Tr4 drain8.09 – 13.1811.24
Tr4 source3.79 – 4.824.17
Tr4 gate3.40 – 4.283.78
Tr4 drain8.09 – 13.1811.24
R23, end at Line amplifier rail, left (C8 +)27.05 – 30.1528.62
R23, end at Tr4 drain8.09 – 13.1811.24
R24, end at Tr4 source3.79 – 4.824.17
C14, end at Tr4 source3.79 – 4.824.17
C8 + lead27.05 – 30.1528.62
R26, end at Line amplifier rail, left (C8 +)27.05 – 30.1528.62
R26, end at +B terminal27.42 – 30.5929.00
C16 + lead8.09 – 13.1811.24
C16 − lead-0.02 – 0.020.00
C17, end at Tr4 drain8.09 – 13.1811.24
C17, end at R30-0.02 – 0.020.00
R30, end at C17-0.02 – 0.020.00
R30 wiper-0.02 – 0.020.00

Line amplifier, right

Test pointExpected (V)TypicalYour readingNote
R111, lead 1-0.02 – 0.020.00
R111, end at C109-0.02 – 0.020.00
C109 + lead10.50 – 12.8611.53 the meter loads this point, so its reading is not used to rank faults: a 10 MΩ meter reads about 11.53 V here, a higher-impedance meter up to 11.87 V
C109 − lead-0.02 – 0.020.00
R116, end at C11117.72 – 20.3519.02
R116, end at Line amplifier rail, right (C108 +)27.04 – 30.2028.62
C111 + lead17.72 – 20.3519.02
R117, end at R11810.73 – 12.7811.76
R117, end at R11617.72 – 20.3519.02
R118, end at R11710.73 – 12.7811.76
R119, end at R11710.73 – 12.7811.76
R119, end at Tr103 base10.50 – 12.8611.53 the meter loads this point, so its reading is not used to rank faults: a 10 MΩ meter reads about 11.53 V here, a higher-impedance meter up to 11.87 V
C110, end at Tr103 base10.50 – 12.8611.53 the meter loads this point, so its reading is not used to rank faults: a 10 MΩ meter reads about 11.53 V here, a higher-impedance meter up to 11.87 V
C110, end at Tr103 emitter11.37 – 13.4312.44
Tr103 emitter11.37 – 13.4312.44
Tr103 base10.50 – 12.8611.53 the meter loads this point, so its reading is not used to rank faults: a 10 MΩ meter reads about 11.53 V here, a higher-impedance meter up to 11.87 V
Tr103 collector3.32 – 4.283.78
R120, end at R12111.38 – 13.4512.46
R120, end at Line amplifier rail, right (C108 +)27.04 – 30.2028.62
R121, end at Tr103 emitter11.37 – 13.4312.44
R121, end at R12011.38 – 13.4512.46
C112 + lead11.38 – 13.4512.46
R122, end at Tr103 collector3.32 – 4.283.78
R125, end at Tr103 emitter11.37 – 13.4312.44
R125, end at C11511.37 – 13.4312.44
C115, end at R12511.37 – 13.4312.44
C115, end at Tr104 drain8.23 – 13.4411.24
C113, end at Tr103 emitter11.37 – 13.4312.44
C113, end at Tr104 drain8.23 – 13.4411.24
Tr104 source3.70 – 4.724.17
Tr104 gate3.32 – 4.283.78
Tr104 drain8.23 – 13.4411.24
R123, end at Tr104 drain8.23 – 13.4411.24
R123, end at Line amplifier rail, right (C108 +)27.04 – 30.2028.62
R124, end at Tr104 source3.70 – 4.724.17
C114, end at Tr104 source3.70 – 4.724.17
C108 + lead27.04 – 30.2028.62
R126, end at Line amplifier rail, right (C108 +)27.04 – 30.2028.62
R126, end at +B terminal27.42 – 30.5929.00
C116 + lead8.23 – 13.4411.24
C116 − lead-0.02 – 0.020.00
C117, end at R130-0.02 – 0.020.00
C117, end at Tr104 drain8.23 – 13.4411.24
R130, end at C117-0.02 – 0.020.00
R130 wiper-0.02 – 0.020.00

SEL REP amplifier, left

Test pointExpected (V)TypicalYour readingNote
C351, end at R351-0.02 – 0.020.00
C351, end at C352-0.02 – 0.020.00
R351, end at C351-0.02 – 0.020.00
R351, end at R352-0.02 – 0.020.00
C352, end at C351-0.02 – 0.020.00
C352, end at R352-0.02 – 0.020.00
R352, end at R351-0.02 – 0.020.00
R352, end at C352-0.02 – 0.020.00
R353, end at C351-0.02 – 0.020.00
C353, end at R351-0.02 – 0.020.00
C354 + lead20.98 – 24.0322.51
C355 + lead0.56 – 0.610.59
C355 − lead-0.02 – 0.020.00
Tr351 emitter0.00 – 0.040.02
Tr351 base0.56 – 0.610.59
Tr351 collector3.93 – 4.964.50
C356, end at Tr351 base0.56 – 0.610.59
C356, end at Tr351 emitter0.00 – 0.040.02
R362, end at Tr351 base0.56 – 0.610.59
R362, end at R3600.57 – 0.640.60
R354, end at SEL REP collector rail, left (C354 +)20.98 – 24.0322.51
R354, end at Tr351 collector3.93 – 4.964.50
R355, end at Tr351 emitter0.00 – 0.040.02
R358, end at SEL REP collector rail, left (C354 +)20.98 – 24.0322.51
R358, end at SEL REP rail, left (C365 +)22.63 – 25.9124.32
C358 + lead8.83 – 13.0911.02
C358 − lead0.00 – 0.040.02
R356, end at C3580.00 – 0.040.02
R356, end at Tr351 emitter0.00 – 0.040.02
C357, end at Tr352 drain8.83 – 13.0911.02
C357, end at R3570.00 – 0.040.02
R357, end at C3570.00 – 0.040.02
R357, end at Tr351 emitter0.00 – 0.040.02
C359, end at Tr352 drain8.83 – 13.0911.02
C359, end at Tr351 collector3.93 – 4.964.50
Tr352 source4.69 – 5.545.12
Tr352 gate3.93 – 4.964.50
Tr352 drain8.83 – 13.0911.02
R359, end at SEL REP rail, left (C365 +)22.63 – 25.9124.32
R359, end at Tr352 drain8.83 – 13.0911.02
R360, end at Tr352 source4.69 – 5.545.12
R360, end at R3620.57 – 0.640.60
R361, end at R3620.57 – 0.640.60
C360 + lead4.69 – 5.545.12
C361, end at Tr352 drain8.83 – 13.0911.02
C361, end at C362-0.02 – 0.020.00
C362, end at C361-0.02 – 0.020.00
C362, end at R3648.83 – 13.0911.02
R363, end at Tr352 drain8.83 – 13.0911.02
R363, end at R3648.83 – 13.0911.02
R364, end at R3638.83 – 13.0911.02
R364, end at C3628.83 – 13.0911.02
R365, end at C361-0.02 – 0.020.00
C363, end at R3638.83 – 13.0911.02
C364, end at C3628.83 – 13.0911.02
C364, end at R367-0.02 – 0.020.00
R367, end at C364-0.02 – 0.020.00
R367 wiper-0.02 – 0.020.00
C365 + lead22.63 – 25.9124.32
R366, end at SEL REP rail, left (C365 +)22.63 – 25.9124.32
R366, end at +B terminal27.42 – 30.5929.00

SEL REP amplifier, right

Test pointExpected (V)TypicalYour readingNote
C371, end at R371-0.02 – 0.020.00
C371, end at C372-0.02 – 0.020.00
R371, end at C371-0.02 – 0.020.00
R371, end at R372-0.02 – 0.020.00
C372, end at C371-0.02 – 0.020.00
C372, end at R372-0.02 – 0.020.00
R372, end at R371-0.02 – 0.020.00
R372, end at C372-0.02 – 0.020.00
R373, end at C371-0.02 – 0.020.00
C373, end at R371-0.02 – 0.020.00
C374 + lead21.02 – 23.9522.51
C375 + lead0.56 – 0.610.59
C375 − lead-0.02 – 0.020.00
Tr371 emitter0.00 – 0.040.02
Tr371 base0.56 – 0.610.59
Tr371 collector3.92 – 4.994.50
C376, end at Tr371 base0.56 – 0.610.59
C376, end at Tr371 emitter0.00 – 0.040.02
R382, end at Tr371 base0.56 – 0.610.59
R382, end at R3800.57 – 0.640.60
R374, end at Tr371 collector3.92 – 4.994.50
R374, end at SEL REP collector rail, right (C374 +)21.02 – 23.9522.51
R375, end at Tr371 emitter0.00 – 0.040.02
R378, end at SEL REP collector rail, right (C374 +)21.02 – 23.9522.51
R378, end at SEL REP rail, right (C385 +)22.67 – 25.8624.32
C378 + lead8.99 – 13.1311.02
C378 − lead0.00 – 0.040.02
R376, end at Tr371 emitter0.00 – 0.040.02
R376, end at C3780.00 – 0.040.02
C377, end at R3770.00 – 0.040.02
C377, end at Tr372 drain8.99 – 13.1311.02
R377, end at Tr371 emitter0.00 – 0.040.02
R377, end at C3770.00 – 0.040.02
C379, end at Tr371 collector3.92 – 4.994.50
C379, end at Tr372 drain8.99 – 13.1311.02
Tr372 source4.67 – 5.555.12
Tr372 gate3.92 – 4.994.50
Tr372 drain8.99 – 13.1311.02
R379, end at Tr372 drain8.99 – 13.1311.02
R379, end at SEL REP rail, right (C385 +)22.67 – 25.8624.32
R380, end at R3820.57 – 0.640.60
R380, end at Tr372 source4.67 – 5.555.12
R381, end at R3820.57 – 0.640.60
C380 + lead4.67 – 5.555.12
C381, end at Tr372 drain8.99 – 13.1311.02
C381, end at C382-0.02 – 0.020.00
C382, end at C381-0.02 – 0.020.00
C382, end at R3848.99 – 13.1311.02
R383, end at Tr372 drain8.99 – 13.1311.02
R383, end at R3848.99 – 13.1311.02
R384, end at R3838.99 – 13.1311.02
R384, end at C3828.99 – 13.1311.02
R385, end at C381-0.02 – 0.020.00
C383, end at R3838.99 – 13.1311.02
C384, end at R387-0.02 – 0.020.00
C384, end at C3828.99 – 13.1311.02
R387, end at C384-0.02 – 0.020.00
R387 wiper-0.02 – 0.020.00
C385 + lead22.67 – 25.8624.32
R386, end at SEL REP rail, right (C385 +)22.67 – 25.8624.32
R386, end at +B terminal27.42 – 30.5929.00

RECORD and SEL REP switching

Test pointExpected (V)TypicalYour readingNote
R325, end at R326-0.02 – 0.020.00
R325, lead 2-0.02 – 0.020.00
R326, end at R325-0.02 – 0.020.00
R326, lead 2-0.02 – 0.020.00

How the bands were made

  • Each band is the spread of 200 simulated boards: resistors ±5 % uniform, +B ±5 % uniform, transistor gain uniform across each type's hFE range, JFET IDSS across the grade band, pinch-off ±20 %. The band runs from the 1st to 99th percentile, widened by ±(0.5 % + 20 mV) for the meter. The typical value is the board with every part at its printed value.
  • The meter is taken as 10 MΩ to ground; where it moves a point by more than 2 % or 50 mV the band is what it reads.
  • The faults are 220 single faults: transistor and JFET leads open or shorted, resistors open or drifted to about twice their value (47k and up, as old carbon resistors drift high), electrolytics shorted or leaky, pot wipers open. Each was simulated alone (each fault alone, nominal parts; a point within a quarter of the band's width of an edge is counted either way).
  • The pots on this board (RECORD LEVEL CAL. and SEL/REP LEVEL ADJ.) sit behind capacitors, so their setting moves no DC reading.

What the simulation assumes

  • Transistor gain (hFE) ranges for the 2SA666 and 2SC644: minimum from catalogue listings, maximum assumed.
  • The 2SK34(D) JFETs' IDSS grade band: assumed, as no grade table was found.
  • The record command: 24 V in record, 0 V otherwise, into PA-286A's 10 kΩ record inputs.
Faults no DC reading can find (36)

These leave every test point in band in every condition. They need a signal test (a scope or a tone through the deck), not a meter.

  • C108 leaky (47µ/35V; about 10 kΩ across it)
  • C8 leaky (47µ/35V; about 10 kΩ across it)
  • R11 open (56k)
  • R11 drifted high (56k, now about twice)
  • R111 open (56k)
  • R111 drifted high (56k, now about twice)
  • R119 drifted high (240k, now about twice)
  • R125 open (24k)
  • R130 wiper open
  • R19 drifted high (240k, now about twice)
  • R25 open (24k)
  • R30 wiper open
  • R351 open (1.2k)
  • R352 open (1.2k)
  • R353 open (600)
  • R354 drifted high (560k, now about twice)
  • R356 open (20k)
  • R357 open (600)
  • R358 drifted high (56k, now about twice)
  • R362 drifted high (150k, now about twice)
  • R363 open (1.2k)
  • R364 open (1.2k)
  • R365 open (600)
  • R367 wiper open
  • R371 open (1.2k)
  • R372 open (1.2k)
  • R373 open (600)
  • R374 drifted high (560k, now about twice)
  • R376 open (20k)
  • R377 open (600)
  • R378 drifted high (56k, now about twice)
  • R382 drifted high (150k, now about twice)
  • R383 open (1.2k)
  • R384 open (1.2k)
  • R385 open (600)
  • R387 wiper open

See also the parts list (every value, with the DC voltage at every lead) and Otari's sheet and layout in Section 6. Simulated in KiCad 10.0.4 and ngspice.